REX-C800 Intelligent Digital Temperature Controller
REX-C800 Intelligent Digital Temperature Controller
Main Technical Index
Input
Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals.
Display
Process Val
- Brand
- NQQK
REX-C800 Intelligent Digital Temperature Controller
Main Technical Index | |
Input | Thermocouple(TC),Resistance Temperature Detector(RTD),Standard Current and voltage signals. |
Display | Process Value(PV),Setting Value(SV):-1999~+1999 |
Output( OUT1,OUT2) Alarm(Alarm1,Alarm2) Auto setting(AT) Display: LED | |
Control way | 1).PID Control(including ON/OFF, position PID and continuous PID) |
(2).Auto Setting Control | |
Accuracy | Measurement Accuracy:±0.5%FS Compensation error of cold terminal:±2°C(amend within 0~50°C by soft) |
Resolution:14bit. Sampling period:0.5Sec. | |
Setting Range | Setting Value(SV):same range with PV |
Proportional Band(P):0~full range(ON/OFF Control when set to 0) | |
Integration Time(I):0~3600Sec (no integral action when set to 0) | |
Derivative Time(D):0~3600Sec(no derivative action when set to 0) | |
Proportional Period:1~100Sec | |
On-off control output hysteretic loop width:1~100°C(or other PV units) | |
Control Output | (1)Currency output: DC 0~10Ma,4~20mA(RL less than 500Ω) |
(2)Voltage output: DC 0-5V,1-5V(RL more than 10K) | |
(3)Relay output: Contact capacity:250V AC 3A(resistive load) | |
(4)Voltage Impulse output:0-12V(applicable for solid state relay SSR) | |
(5)Silicon Controlled Rectifier(SCR) output: zero-cross triggering or phase-shift triggering(resistive load) | |
(6)Output Contact Capacity:250V AC 3A | |
Alarm output | 2 groups output at most,12 modes |
Inanlating resistanle | more than 50MΩ(500V DC) |
Inanlating intensity | 1500V AC/min |
Power consumed | less than 10 VA |
Work condition | 0~50°C,30~85RH,no corrosive gas |
Weight | abt.0.5Kg(CXTA type) |
Model Name | |
1.Outline dimension: See the outline dimension picture | 7.Second control output( OUT2) (Cooling side) |
2.serial number | No mark: when the control mode is F or D |
3.Control Mode | M: Relay contact output T: Thyratron output |
0:PID operation and auto calculating (reverse operation) | V: Voltage impulse output 8: Current output(IC 4-20mA) |
1:PID operation and auto calculating(Forward operation) | T: Thyratron output |
4.Input mode:Refer to input Range Table | 8: Current output(IC 4-20mA) |
0:TC,RTD | 8.First alarm(ALM1), |
1:standard current 4~20mA,0~20mA | 9.Second alarm (ALM2) |
2:standard voltage:0~5V DC,1~5V DC | N:no alarm |
3:electronic sigral code:(Ω) | A: Upper-limit deviation alarm |
5.femperature unit | B: Lower-limit bias alarm |
0:degree celsius (°C) | C: Upper/lower limit bias alarm |
1:Fahrenheit (F) | D: alarm in area |
6.First control output(OUT1) (Heating side) | E: Standby upper-limit bias alarm attached |
M: Relay contact output | F: Standby lower-limit bias alarm attached |
V: Voltage impulse output | G: Standby upper/lower limit bias alarm |
T: Thyratron output | H: Upper-limit input value alarm |
8: Current output(IC4-20mA) | J: lower-limit input alarm |
G: Thyratron driving & triggering output | K: Standby upper-limit input alarm attached |
L: Standby lower-limit input alarm attached |
Extemal dimensin | |||||||||
REX-C100 | CXT -3000 | A | B | C | D | E | F | G | H |
C100 | CXTG | 48 | 48 | 10 | 100 | 45 | 45 | 80 | 80 |
C400 | CXTE | 96 | 48 | 10 | 100 | 92 | 45 | 116 | 80 |
C410 | CXTF | 48 | 96 | 10 | 100 | 45 | 92 | 80 | 116 |
C700 | CXTD | 72 | 72 | 10 | 100 | 68 | 65 | 90 | 96 |
C900 | CXTA | 90 | 90 | 10 | 100 | 92 | 92 | 116 | 116 |
C800 | CXTM | 80 | 160 | 10 | 100 | 76 | 152 | 105 | 190 |
Trade Information:
Trade Terms | FOB ,CIF ,CFR,EXW,DDP |
Payment terms | T/T,L/C,Western union,Paypal,Escrow,MoneyGram |
Payment conditions | 30% deposit in advance,70% balance before shipping. |
Delivery time | 3-7working days after deposit,2-4 working days for inventory |
Packing | Neutral carton,Wooden case for large size |
Shipping | By sea,by air and by express delivery |